Sterikon Vet Care Warranty

All Sterikon Vet Care instruments are guaranteed against defects in materials and workmanship 

for a period of two (2) years from the date of purchase.

Any instrument found to be defective under normal use and for its intended surgical purpose

during the warranty period will be repaired or replaced at no charge, at Sterikon Vet Care’s

discretion.

This warranty does not cover damage resulting from misuse, abuse, improper handling,

improper maintenance, unauthorized modification, corrosion, accidental damage, normal wear

and tear, or use for purposes other than those for which the instrument was designed.

Sterikon Vet Care is committed to providing high-quality veterinary surgical instruments that

deliver exceptional performance, durability, and reliability.

CARE &  MAINTENANCE OF INSTRUMENTS

Sterikon vet care always manufactures Surgical Instruments according to established

international patterns. These instruments must be used only for the intended surgical purpose

by qualified surgeons or medical practicing students under supervision by experienced experts.

Inappropriate use may result in damage of instruments.

PROCESSING AND REPROCESSING

Always read and follow the instructions of use and keep them for future reference for the

products long life, reliability and better use.

Sterilize instruments before their use. After use, clean, lubricate and sterilize the instrument. A

fully validated mechanical cleaning procedure should be used wherever possible. Instruments

can be cleaned by ultrasonic treatment or a specially designed detergent can also be used for

cleaning in which surfaces must be in contact with the detergent, channels, lumen, inner cavities

and openings. A soft plastic brush or a fluff free cloth may be used to assist manual cleaning.

Rinse thoroughly, carefully and If possible use demineralized water for cleaning.

DRYING & LUBRICATION

Dry sufficiently after rinsing using a soft absorptive cloth and inaccessible parts dried with

compressed air. Treat the instruments joints, ratchets, threads and any moving parts based on

paraffin oil designed for the purpose. All instruments must be stored in dry, clean and protected

environment when not in use.

STERILIZATION

All instruments must be subjected to a fully validated steam sterilization process after

decontamination and before use. The sterilizer must conform to EN 285. The process must be

validated in conformance with EN 554. A fractioned vacuum process required the following

minimum parameters 5 minutes, 134°C and 2 bar pressure. When instruments are hot-air

sterilized, the temperature should be 180°C and not exceed 200°C Corroded instruments

should be discarded immediately and not be used.